Article ID: 579
Last updated: 19 Nov, 2021
York Gas Furnaces: TG9S Re: Diagnostic Codes / Fault Codes These York gas furnaces have a control board inside the furnace blower compartment that will flash a diagnostic code that shows the operating status of the furnace.
Fault Code Retrieval: With no thermostat call push and release the LAST ERROR button. The LED will flash up to 5 stored fault codes, beginning with the most recent. If there are no codes in memory, the LED will flash two green flashes. Clear the Fault Codes: Push and hold the LAST ERROR button for at least five seconds. The LED will flash three green flashes when the memory has been cleared.
This article was:
Helpful |
Not helpful
Report an issue
Article ID: 579
Last updated: 19 Nov, 2021
Revision: 5
Access:
Public
Views: 8281
Comments: 0
|
Powered by KBPublisher (Knowledge base software)