Knowledgebase
YP9C / PC9
YP9C - Flashing Code 7
York Gas Furnace: YP9C / PC9 Re: Flashing Code 7 Code 7 = Failure to Sense Flame (3 attempts) ► If flame cannot be established in three tries, the control will lockout for one hour and then automatically try again to light. Qty Possible Causes: 5 Dirty Flame Sensor 2...
23 Jan, 2023 Comments: 0
YP9C - Flashing Code 8
York Gas Furnace: YP9C Re: Flashing Code 8 Code 8 = Flame was established but then lost 5 times. Qty Possible Causes: 2 Dirty Flame Sensor Exhaust Leak in Cabinet CHECKOUT: 1. Check Ignition Sequence If the furnace is running, turn the thermostat off and...
21 Nov, 2018 Comments: 0
YP9C - Flashing Code 11
York Gas Furnace: YP9C Re: Flashing Code 11 This indicates that a primary limit switch has opened and has remained open for more than five minutes. This condition is usually associated with an air circulation failure. ► Code 11 is a Hard-Lockout which requires cycling 24VAC power to the...
6 Dec, 2021 Comments: 0

Prev 2 / 2 Next →
1 2(Page 2 of 2)