Y91E Diagnostic Codes / Fault Codes
York Gas Furnaces: Y91E Re: Diagnostic Codes / Fault Codes These York gas furnaces have a control board inside the furnace blower compartment that will flash a diagnostic code that shows the operating status of the furnace. Diagnostic Codes: Slow Green Normal Operation - no...
5 Dec, 2024
Comments: 0
Y91E - Flashing Code 4
York Gas Furnace: Y91E Re: Flashing Code 4 Code 4 = Main limit switch has opened its normally closed contacts. The control will operate the supply air blower and inducer while the open limit condition exists. ► If the limit switch has not closed within five minutes, the control will assume...