Goodman Gas Furnace: GMS9 Re: Flashing Code 3 If, after the vent blower is energized, the pressure switch does not close, the control will keep the blower on and wait for the switch to close. The diagnostic code for this problem is 3 short flashes followed by a pause. ► There are 2 pressure switches in the furnace: One connected to the Inducer, and one connected to the collector box. ► Only the Inducer Pressure Switch will cause a Code 3. (The condensate switch breaks power to the gas valve and will cause a Code 1). ► The diagnostic code will go away once the pressure switch closes.
CHECKOUT: 1. Check Control Board
3. Check "Inducer" Pressure Switch