Knowledgebase

Making Noise Running High Pressure (Heating)

Article ID: 34
Last updated: 16 Nov, 2017

Make:  York

Model or Series:  YHJF36 with AHX42

Type:  Heat Pump and Air Handler

Problem Description:  Unit making noise & head pressure a little high

Observed Symptoms:  

  • Head pressure around 350 psi
  • Head pressure drops when electric heat comes on
  • Indoor blower speed increases when electric heat comes on

Solution:  Moved "Y" from the thermostat from Y1 to Y/Y2 at the air handler


Additional Information:  

  • AHX air handler has 2 speeds - High and Low
  • Low speed (Red wire) is for G and Y1
  • High speed (White wire) is for Y/Y2 and Aux Heat
    • Y/Y2 should be used on all single stage applications
This article was:   Helpful | Not helpful