York Gas Furnace: PM9 Modulating PSC

Re: Control Board Replacement

The PM9 furnace is a modulating gas furnace with a standard, PSC blower motor.

  • The original control board had a differential pressure transducer built into the bottom of the board.
  • The new control board utilizes an external pressure transducer and uses a different modulating signal for the gas valve.

If the original control board must be replaced, a control board kit is required.


The new kit consists of the following:

  • New Control Board
  • New Gas Valve
  • New Transducer
  • Wiring Harnesses
  • Wiring Diagram
  • Configuration Plugs
    • The correct plug must be installed to match the furnace model#.