Water Leak / Clear Condensate Pan Covers
York Gas Furnace Re: Water Leak / Clear Condensate Pan Covers All of the 33" gas furnaces originally came with a clear, plastic condensate pan cover. Over time, the clear plastic pan has a tendency to crack and cause condensate leakage inside the furnace cabinet. Any clear condensate pans...
14 Feb, 2020
Comments: 0
Gas Furnace - Blown Low Voltage Fuse
Gas Furnace Re: Blown Low Voltage Fuse The low voltage fuse provides protection for the control board and other low voltage components in the case of high amperage caused by a low voltage short or excess component load. ► The fuse must be sized per the "VA" of the transformer. Amps = VA...
19 Apr, 2018
Comments: 0
TM9X/TM9E - Diagnostic Codes
York Gas Furnaces: TM9X/TM9E Re: Diagnostic Codes / Fault Codes These York gas furnaces have a control board inside the furnace blower compartment that will flash a diagnostic code that shows the operating status of the furnace. Diagnostic Codes: Slow Green Normal Operation -...
1 Dec, 2018
Comments: 0
York Gas Furnace - Code 1
York Gas Furnace Re: Flashing Code 1 Code 1 = Flame sensed with no call for heat. ► In a Code 1 situation, the furnace control board thinks that the gas valve is stuck on and the flame is still burning without a call for heat. Therefore, when a control board goes into a code 1, it will lock...
15 Jun, 2020
Comments: 0
York Gas Furnace - Code 2
York Gas Furnace Re: Flashing Code 2 (Assuming original control board) Code 2 = Pressure switch stuck closed The furnace pressure switch should only close when the inducer fan output is energized. If control board is not energizing the inducer fan output and the switch is closed, the board...
15 Jun, 2020
Comments: 0
TM9X/TM9E - Flashing Code 3
York Gas Furnace: TM9X/TM9E Re: Flashing Code 3 Code 3 = Furnace Pressure Switch failed to close on a call for heat. This gas furnace has two pressure switches (PS1 & PS2) - a higher pressure switch to monitor the negative pressure at the inducer motor, and a lower pressure switch to...
9 Mar, 2023
Comments: 0
TM9X/TM9E - Flashing Code 4
York Gas Furnace: TM9X / TM9E Re: Flashing Code 4 Code 4 = Main limit switch has opened its normally closed contacts. The control will operate the supply air blower and inducer while the open limit condition exists. ► If the limit switch has not closed within five minutes, the control will...
21 Nov, 2023
Comments: 0
TM9X/TM9E - Flashing Code 5
York Gas Furnace: TM9X/TM9E Re: Flashing Code 5 Code 5 = Roll-out switch circuit has opened or low voltage fuse blown. The control will operate the supply air blower and inducer while the open limit condition exists. ► An LP Gas Pressure Switch may be wired in series with the roll-out...
15 Jun, 2020
Comments: 0
TM9X/TM9E - Flashing Code 6
York Gas Furnace: TM9X / TM9E Re: Flashing Code 6 Code 6 = Pressure switch opened 4 times during a run cycle. ► This is a "Soft Lockout" which will automatically reset after 1 hour. Qty Possible Causes: 2 Bad Inducer Motor 1 Water in Vent 4 Clogged drain...
22 Nov, 2023
Comments: 0
TM9X/TM9E - Flashing Code 7
York Gas Furnace: TM9X/TM9E Re: Flashing Code 7 Code 7 = Failure to Sense Flame (3 Failed Ignition Attempts) Qty Possible Causes: 1 Dirty Flame Sensor 1 Bad Glow Plug 1 Clogged Burners 1 No or Low Gas Pressure 1 Bad Gas Valve Bad...
25 Apr, 2024
Comments: 0
|
Powered by KBPublisher (Knowledge base software)