Rheem Gas Furnace: R801 Re: Diagnostic & Fault Codes The furnace control comes standard with a 7-segment diagnostic display. During Standby mode (with no faults), the display will read "0". During normal Heating, Cooling or Continuous Fan operation, a letter will be displayed to describe the mode of operation:
All lockout conditions can be cleared immediately provided that the original fault causing the lockout is cleared and power to the unit is cycled off and then back on again or (soft lockout only) if a heat call is cycled off for greater than 2 seconds but less than 20 seconds. 5-Minute Lockout A five minute “soft” lockout will be initiated if the pressure switch fails to close after 60 seconds of continuous inducer operation at the beginning of a normal heat cycle (pressure switch proving period). The seven-segment display will display the appropriate fault. Lockout will automatically be reset after five minutes. 1-Hour Lockout A one hour “soft” lock out will be initiated when:
The seven-segment display will alternately display “10” and the code number for the fault causing the lockout. Lockout will automatically be reset after one hour. Hard Lockout Three conditions shall cause a hard lockout: