Ducane Gas Furnace: 92AF

Re: Lockout Codes

Red Light Description
Off No Power or Control Failure
On Power On - Normal Operation
1 Flame Present with Gas Valve Off
2 Pressure Switch Stuck Closed
3 Pressure Switch Stuck Open
4 High Limit Switch Open
5 Roll-Out Switch Open
6 Pressure Switch Cycle Lockout
7 Failure to Ignite
8 Flame Loss
9 Incorrect Polarity