York Heat Pump: YHM
Re: Fault Codes
The fault and status codes for the YHM heat pump are displayed on the small control board mounted beneath the large inverter board.
LED |
Seg 1 |
Seg 2 |
Description |
Solid |
0 |
0 |
Control Failure |
Operational Faults |
Solid |
0 |
1 |
Hi Pressure Fault (not in lockout) |
2 |
0 |
2 |
Hi Pressure Soft Lockout (last mode HP) |
3 |
0 |
2 |
Hi Pressure Hard Lockout (last mode HP) |
2 |
0 |
3 |
Hi Pressure Soft Lockout (last mode defrost) |
3 |
0 |
3 |
Hi Pressure Hard Lockout (last mode defrost) |
2 |
0 |
4 |
Low Pressure Soft Lockout |
3 |
0 |
4 |
Low Pressure Hard Lockout |
Solid |
0 |
6 |
Low Voltage (less than 19.2V) |
Solid |
0 |
7 |
Low Voltage (less than 16V) |
Solid |
0 |
8 |
Inverter Communication Fault |
Sensor/Switch Faults |
Solid |
0 |
9 |
OD Sensor Failure (Short) |
Solid |
1 |
0 |
OD Sensor Failure (Open) |
Solid |
1 |
1 |
Liquid Line Sensor Failure (Short) |
Solid |
1 |
2 |
Liquid Line Sensor Failure (Open) |
Solid |
1 |
3 |
Discharge Sensor Failure (Short) |
Solid |
1 |
4 |
Discharge Sensor Failure (Open) |
Solid |
1 |
5 |
Hi Discharge Temperature |
Solid |
1 |
6 |
Low Discharge Temperature |
Wiring-Related Faults |
Solid |
1 |
8 |
"O" Received in AC-Only Mode |
Solid |
1 |
9 |
"W" Received in Cooling Mode |
Solid |
2 |
0 |
"W" and "O" Received in AC-Only Mode |
Solid |
2 |
4 |
"W" and "O" Received in Cooling Mode |
Mismatch Speed Faults |
Solid |
2 |
5 |
Compressor Start Failure |
Solid |
2 |
6 |
OD Fan Start Failure |
Operating Threshold Errors |
Solid |
2 |
7 |
OD Temperature 109 - 125 deg. (Cool Mode) |
Solid |
2 |
8 |
OD Temperature > 125 deg. (Cool Mode) |
Solid |
2 |
9 |
OD Temperature < 35 deg. (Cool Mode) |
Inverter - Major Faults |
Solid |
3 |
1 |
Compressor Inverter Fault |
Solid |
3 |
2 |
Fan Inverter Fault |
Solid |
3 |
3 |
Loss of Communication with Inverter |
Solid |
3 |
4 |
DC Over-Voltage |
Solid |
3 |
5 |
DC Under-Voltage |
Solid |
3 |
6 |
Compressor Inverter Over-Current |
Solid |
3 |
7 |
IPM Over-Temperature |
Solid |
3 |
8 |
DC Over-Voltage - IPM |
Solid |
3 |
9 |
DC Under-Voltage - IPM |
Solid |
4 |
0 |
Compressor Speed Mis-Alignment |
Solid |
4 |
1 |
Phase Lost Detected by Speed |
Solid |
4 |
2 |
Phase Lost Detected by Current |
Solid |
4 |
3 |
Compressor IPM Fault - by IGBT Voltage |
Solid |
4 |
4 |
inverter PWM Logic Error |
Solid |
4 |
5 |
Inverter PWM Initialization Error |
Solid |
4 |
6 |
Compressor Inverter Shunt Resistor Unbalanced |
Solid |
4 |
7 |
Fan Inverter IPM Fault |
Solid |
4 |
8 |
Fan Inverter Misalignment 7 Locked Rotor |
Solid |
4 |
9 |
Fan Inverter Phase Lost |
Solid |
5 |
0 |
Fan Inverter DC bus under/over voltage |
Solid |
5 |
1 |
Fan Inverter Over Current |
Solid |
5 |
2 |
Compressor IPM Fault - by Low IGBT Voltage |
Solid |
5 |
3 |
Analog Digital Converter Offset Error |
2 |
5 |
4 |
Inverter Drive Soft Lockout (3 faults in 30 min) |
3 |
4 |
4 |
Inverter Drive Hard Lockout (4 soft lockouts in 2 hrs) |
Solid |
5 |
6 |
Crankcase Heater Fault |
Inverter Minor Faults |
Solid |
6 |
0 |
IPM Over-Temperature (Speed Limiting) |
Solid |
6 |
1 |
DC Low Voltage (Speed Limiting) |
Solid |
6 |
2 |
Compressor Over-Current (Speed Limiting) |
Solid |
6 |
3 |
DC Voltage Low (Speed Reducing) |
Solid |
6 |
4 |
Compressor Over-Current (Speed Reducing) |
Solid |
6 |
5 |
IPM Over-Temperature (Speed Reducing) |