Nordyne Gas Furnace: G6RC/FG6RC
Re: No Heat - Flashing Code 4
Code 4 = Three consecutive failed ignition attempts (failed to sense flame).
Qty |
Possible Causes: |
|
Dirty Flame Sensor |
|
Bad Glow Plug |
|
Clogged Burners |
|
No or Low Gas Pressure |
1 |
Bad Gas Valve |
CHECKOUT:
1. Check Ignition Sequence
- If the furnace is running, turn the thermostat off and allow the furnace to cool and the blower to stop operating.
- Initiate a call for heat from the thermostat and monitor the ignition sequence.
- 1. The inducer motor should start with no difficulty.
- 2. The pressure switch should close within a couple seconds of the inducer starting.
- 3. The glow plug should energize within 30 seconds of the pressure switch closing.
- 4. The gas valve should open within 20 seconds of the glow plug energizing.
2. Check Ignition
- Visually inspect the burners during ignition.
- The burners should light smoothly with little or no delay from the glow plug to the flame sensor.
- Make sure the flame sensor comes in good contact with the flame.
3. Check Glow Plug
- Look for any visual cracks.
- Unplug the 2-wire connector to the glow plug.
- Use a meter to test resistance of the glow plug.
- No Resistance = Bad Glow Plug
- Resistance ⇒ Continue
- Start an ignition sequence.
- Check for 120VAC power on the 2-wire plug feeding the glow plug during an ignition sequence.
- No Power = Bad Ignition Control
- Power Present + No Glow = Bad Glow Plug
4. Check Gas Pressure / Valve
- Check for 24VAC between the two wires at the gas valve at the point of ignition.
- Power Present ⇒ Check gas pressures (below)
- No Power ⇒ Check for 24VAC at the control board 9-pin plug between Pin #2 (Brown) and Pin #4 (Yellow)
- No Power = Bad Control Board
- Power at the Board + No Power at the Gas Valve = Bad Wiring
- Inlet Gas Pressure
- Check the inlet gas pressure with the furnace off.
- Minimum Pressure = 5" w.c. for Nat. gas, and 11" w.c. for propane.
- Low Pressure = Bad Meter or Regulator
- Monitor the inlet gas pressure as the furnace attempts to ignite.
- Pressure Drops Below Minimum = Bad Meter/Regulator or Restricted Gas Line
- Manifold Gas Pressure
- Check the manifold pressure when the furnace attempts to ignite.
- Normal Pressure = 3 - 3.5" w.c. for Nat. Gas, 9 - 11" w.c. for LP
- No Gas Pressure = Bad Gas Valve
- Low Gas Pressure ⇒ Increase Manifold Gas Pressure
- Normal Gas Pressure + No or Delayed Ignition = TG9S Igniter Issue or Clogged Burners
5. Check Flame Sensor
- On the multi-meter:
- Switch the test leads to "COM" and "mA".
- Set the meter on DC 200ù.
- Disconnect the wire from the flame sensor.
- Place one meter lead on the flame sensor terminal and the other on the flame sensor wire.
- Check the reading when the burners ignite.
- Normal Reading = 3.7 mA
- Low Flame Signal Warning = 1.5 MicroAmp
- Lockout Point = 0.1 MicroAmp
- Low Reading = Dirty Flame Sensor ⇒ Clean the Flame Sensor & Re-check
- CAUTION! Move meter leads back to "COM" and "V" before proceeding!