Gas Furnace: G6R, GM

Re: Lockout Codes

Red Light Description
On Power On
1 Limit switch open
2 Pressure switch stuck open
3 Pressure switch stuck closed
4 Ignition Failure
5 Reversed Polarity
Continuous Flash Flame sensed with no call for heat
Yellow Light Description
Continuous Flash Low Flame Signal
On Flame Sensed

Replacement furnace control boards:

  • Partners Choice Part# 903106
  • ICM2805A
  • Honeywell S9200U