Nordyne , Kenmore or Gibson Gas Furnace Diagnostic Codes
Gas Furnace: G6R, GM Re: Lockout Codes Red Light Description On Power On 1 Limit switch open 2 Pressure switch stuck open 3 Pressure switch stuck closed 4 Ignition Failure 5 Reversed Polarity Continuous Flash Flame sensed with no...
22 Oct, 2019
Comments: 0
G6RC - Flashing Code 1
Nordyne Gas Furnace: G6RC Re: Flashing Code 1 Code 1 = Limit switch open If the limit control opens, the burners will be de-energized and the air circulation and vent blower will be turned on until the limit closes. The diagnostic light code for this is one short flash followed by a...
12 Feb, 2026
Comments: 0
Nordyne - Code 2 or Code 3 - Caused by Gas Valve
Make: Nordyne Model or Series: FG6RK Type: 80% Gas Furnace Problem Description: Furnace locks out on either a Code 2 or 3. Observed Symptoms: Inducer motor shuts-off when gas valve energizes. Solution: Replaced Universal Electronic Ignition Gas Valve Additional Information: Removed...
20 Mar, 2017
Comments: 0
G6R - Flashing Code 4
Nordyne Gas Furnace: G6RC/FG6RC Re: No Heat - Flashing Code 4 Code 4 = Three consecutive failed ignition attempts (failed to sense flame). Qty Possible Causes: Dirty Flame Sensor 3 Bad Glow Plug Clogged Burners No or Low Gas Pressure 1 Bad...
29 Dec, 2025
Comments: 0
|