York Heat Pump - Not Defrosting / Frozen
York Heat Pump: YMA Re: Not Defrosting / Frozen These units use a Demand Defrost control board. The board uses an Ambient (outdoor) Sensor and Liquid Line Sensor to determine the proper conditions for defrost to occur. ♦ VERY IMPORTANT! The YMA heat pump was originally produced with R-22...
3 Dec, 2018
Comments: 0
YMA - Defrost Board Replacement
York Heat Pump: YMA Re: Replacement Demand Defrost Control Board - S1-33101975102 INSTALLATION Power off unit totally - 240V & 24V Pull unit disconnect. Disconnect high voltage power to air handler Record positions and colors of original wiring. Remove old defrost control...
3 Dec, 2018
Comments: 0
YMA - Outdoor Unit Starts Then Shuts Off
York Heat Pump: YMA **INCOMPLETE** Re: Outdoor Unit Starts Then Shuts Off The contactor on the outdoor unit pulls-in and the unit starts running, but shuts off after a short runtime. Qty Possible Causes: 1 Bad Hi Pressure Switch Bad Low Pressure Switch ...
2 May, 2019
Comments: 0
YMA - Contactor Won't Energize - Locked-Out
Heat Pump: YMA Re: Contactor Won't Energize Thermostat calling for heating or cooling, but the contactor on the outdoor unit doesn't pull-in. No Compressor Operation No Outdoor Fan Operation Qty Possible Causes: 1 Safety Lockout Bad Hi Pressure Switch ...
3 Jan, 2020
Comments: 0
|
Powered by KBPublisher (Knowledge base software)