ERROR CODES AT INDOOR UNIT
CODE DESCRIPTION
EE Indoor PCB Malfunction. Replace indoor main board.
E2 Anti-freeze Protection. Outdoor ambient temperature is too low.
E4 Discharge temperature sensor out of range.
E5 Low voltage protection
E6 Communication malfunction
E8 System overload protection
U8 Indoor board malfunction
H6 Indoor motor malfunction
C5 Missing jumper from indoor board
F1 Return air temperature sensor malfunction
F2 Indoor pipe temperature sensor malfunction
F3 Outdoor ambient temperature sensor malfunction
F4 Condenser temperature sensor malfunction (open or shorted)
F5 Discharge temperature sensor malfunction (open or shorted)
F6 Overload limit, compressor speed reduction
F8 Over current compressor speed reduction
F9 Compressor discharge temperature high, compressor speed reduction
PH Over voltage protection
U5 Current detection malfunction
P5 Compressor current protection
H1 Defrosting
H3 Compressor overload protection
H4 System overload protection
H5 IPM protection
HC PFC (power factor correction) board protection
H7 Compressor speed reduction
H0 Ambient temperature cut off range
LC Compressor start-up failure
U1 Compressor phase detection error