Knowledgebase

CZH - High Pressure Lockout - Condenser Fan not Working

Article ID: 282
Last updated: 4 Sep, 2019

York Air Conditioner: CZH

Re: High Pressure Lockout / Condenser Fan not Working

The CZH air conditioner utilizes a two-stage scroll compressor and a variable-speed condenser fan motor.

If the condenser fan motor fails to operate, the unit will lock-out on High Pressure.


Qty Possible Causes (From Most to Least Likely):
3 Bad Motor / Module
Bad Control Board


CHECKOUT:

1. Check Outdoor Fan

  • Check the fan motor on the outdoor unit.
  • Set the thermostat to call for cooling.
  • Inspect the outdoor unit and make sure the outdoor fan is operating.

2. Check Pressures

This article was:   Helpful | Not helpful
Report an issue
Article ID: 282
Last updated: 4 Sep, 2019
Revision: 5
Access: Public
Views: 35
Comments: 0