GR6GD
Nordyne GR6GD Package Unit

Nordyne
Nordyne / Partners Choice - R4 & R6 Lockout Codes
Nordyne / Partners Choice - R4 & R6 Series Re: Lockout Codes Red Light Status Description 1 Limit Circuit Open 2 Pressure switch stuck open 3 Pressure switch stuck closed 4 Ignition failure 5 Reversed Polarity Continuous Flash Flames...
29 Aug, 2017 Comments: 0
Nordyne / Partners Choice - Code 1 Limit Trip or Open
Nordyne / Partners Choice Package Units: R4GA Re: Flashing Code 1 - Open Limit Circuit The R4GA package unit has two limits wired in series: Primary Heat Exchanger Limit (auto reset) - 165 deg Burner Roll-Out Limit (manual reset) Possible Causes (From Most to Least Likely): Primary...
12 Jan, 2017 Comments: 0
Nordyne / Partners Choice - 240V Glow Plug / Ignitor
Nordyne / Partners Choice Package Units Re: 240V Glow Plug / Ignitor / Igniter Nordyne gas heating package units use a 240V glow plug. It is very important to replace the glow plug with an equivalent 240V glow plug. A 120V glow plug will quickly fail or EXPLODE!