Honeywell Thermostat: TH6220U/TH6320U T6 Pro

Re: Add-On Heat Pump Setup

To enter Installer Setup:

  • Press and hold the "Center" button and the "+" button together for 3 seconds.
  • Press "Select" to enter Setup.
  • Press "Select" to cycle through setup options.
  • Press "+" or "-" to change values.
  • Press "Select" to confirm changes or "Back" to ignore changes.
  • To Finish and Save changes, press "Home".

Setup# Function Options
120 Schedule Options
  • 0 = Non-Programmable
  • 2 = 5/2 Programmable
  • 3 = 5/1/1 Programmable
  • 4 = 7 Day Programmable
125 Temperature Scale
  • 0 = Farenheit
130

Outdoor Sensor

  • 1 = Wired Outdoor Sensor
200

Heat Equipment

  • 2 = Heat Pump
205 Heat Type
  • 7 = Air to Air Heat Pump
218 Reversing Valve
  • 0 = O/B Energizes in Cool
  • 1 = O/B Energizes in Heat (Rheem, Ruud or Bosch)
220 Cool Stages
  • 1 or 2 (TH6320 Only)
221 Heat/Backup Stages
  • Backup Stages = 1
230 Heat Fan Control
  • 2 = Thermostat Controls Fan
255 Backup Heat Source
  • 2 = Gas Furnace
256 Em Heat Source (TH6320 Only)
  • 2 = Gas Furnace
260 Fossil Fuel Control
  • 0 = Thermostat Controls 
300 System Changeover
  • 1 = Automatic
303 Auto Changeover Differential
  • 3 Deg F.
340 Backup Heat Droop
  • 2 Deg F.
350 Backup Ht Upstage Timer
  • 0 = Off
355 Compressor Lockout
  • 40 Deg F 
356 Aux Heat Lockout
  • -- = Off
365 Cool 1 Cycle Rate
  • 1 to 6
366 Cool 2 Cycle Rate
  • 1 to 6
370 Heat 1 Cycle Rate
  • 1 to 12
371 Heat 2 Cycle Rate
  • 1 to 12
375 Aux Ht Cycle Rate
  • 1 to 12
387 Short-Cycle Time
  • 3 Min
425 Intelligent Recovery
  • 1 = Yes
430 Min Cool Setpt
  • 65 Deg F.
431 Max Heat Setpt
  • 80 Deg F.
435 Keypad Lockout
  • 0 = None
500 Wired Indoor Sensor
  • 0 = No
702 Air Filter Qty
  • 1
711 Filter 1 Timer
  • 0 = Off
712 Filter 2 Timer
  • 0 = Off
1400 Backlight
  • 1 = Continuous
1401 Brightness
  • 1 to 5
1410 Clock
  • 12
1415 Daylight Savings
  • 1 = On
1420 Temperature Offset
  • 0 Deg F.