Knowledgebase

Configure 2-Heat, 1 Cool Heat Pump

Article ID: 678
Last updated: 6 Feb, 2023

Honeywell Thermostats: Prestige IAQ

Re: Configure 2-Stage Heat, 1-Stage Cool Heat Pump


Step 1: Enter Configuration Screen

First-Time Power-Up → Step 2. Enter Setup Information

Service Configuration ⇒ Go into "Installer Setup"

  • From the HOME Screen press the MENU tab
  • Scroll down and select "Installer Options"
  • Enter the Factory Password
  • Select "Installer Setup"

Step 2: Enter Setup Information below:

Setup# Description Option
1000 LANGUAGE English
1010 APPLICATION "residential" or "commercial"
1030 THERMOSTAT NAME Select Appropriate Name
110 SYSTEM ZONING Not Zoned
** CONNECT **
EQUIPMENT INTERFACE NAME EIM
CONNECT OTHER REDLINK No
1040 SCHEDULING OPTION Programmable
1050 TEMPERATURE SCALE "fahenheit"
1060 OUTDOOR AIR SENSOR No (Optional)
2000 HEATING SYSTEM "heat pump"
2010 HEATING EQUIPMENT "air to air heat pump"
2060 REVERSING VALVE "o (o/b on cool)"
2070 STAGES 1, 1
2180 BACKUP HEAT TYPE "electric"
3000 SYSTEM CHANGEOVER "automatic", 3deg
3010 CONTROL OPTIONS "advanced options"
3021 FINISH WITH HIGH HEAT No
3090 BACKUP HEAT DROOP 2.0 deg
3110 UPSTAGE TIMER BACKUP HT Off
3120 OUTDOOR TEMP LOCKOUTS Off, Off
3140 COMPRESSOR CYCLES STG 1 3
3160 BACKUP HEAT CYCLES PER HR 9
3240 COMPRESSOR OFF TIME 3 minutes
3260 EXTENDED FAN RUN TIMES 60, 60
4000 SCHEDULE PERIODS "4 periods per day"
4010 PRE-OCCUPANCY PURGE Off
4020 TYPE OF OVERRIDE standard
4030 OVERRIDE DURRATION 4 hours
4050 MIN HEAT RECOVERY RATE 3º/hr
4070 MIN COOL RECOVERY RATE 5º/hr
4090 ADAPTIVE RECOVERY Yes
4100 TEMPERATURE RANGE STOPS 64 deg, 82 deg
4110 KEYPAD LOCKOUT "Unlocked"
5000 WHAT SENSORS CONNECTED None
6000 WHAT DRY CONACTS  None
7000 FILTER TYPE "media"
7020 NUMBER OF AIR FILTERS 1
7110 AIR FILTER "reminder-off"
8000 HUMIDIFIER TYPE "none" or "bypass-fan/pwrd"
8030 HUMIDIFIER WIRING "t-stat terminal U1"
8050 WINDOW PROTECTION Off
8060 USE HIMIDIFIER IN HEAT MODE Yes
8070 HUMIDIFIER CONTROL "hum when heat is on"
8100 HUMIDIFIER PAD "reminder-off"
9000 DEHUM EQUIPMENT "A/C with high fan"
9070 DEHUM OVER COOLING LIMIT 1 deg
9180 DEHUM AWAY MODE "not allowed"
9210 DEHUMIDIFIER FILTER "reminder-off"
10000 VENTILATION TYPE "none"
10170 VENTILATION FILTER "reminder-off"
11000 NUMBER OF UV DEVICES 0
12000 CUSTOM REMINDERS
14000 CLOCK FORMAT "12 hour"
14010 DAYLIGHT SAVING TIME On
14020 INDOOR OFFSETs 0 deg, 0%
15000 DEALER INFORMATION Name : "GHAC"
15000 DEALER INFORMATION Phone: 606-836-8143
15010 MORE DEALER INFORMATION email: 
15010 MORE DEALER INFORMATION website: www.ghacinc.com
15020 DEALER MESSAGE
  • Humidifier Options Only
  • Commercial Options Only

Step 3: Press "Done"

  • "Do you want to exit Installer Setup? Press "Yes"
  • "Do you want to save changes?" Press "Yes"

Step 4: Press "HOME" to go back to the Home Screen.