Honeywell Thermostats: Prestige IAQ
Re: Configure 2-Stage Heat, 1-Stage Cool Heat Pump
Step 1: Enter Configuration Screen
First-Time Power-Up → Step 2. Enter Setup Information
Service Configuration ⇒ Go into "Installer Setup"
- From the HOME Screen press the MENU tab
- Scroll down and select "Installer Options"
- Enter the Factory Password
- Select "Installer Setup"
Step 2: Enter Setup Information below:
| Setup# |
Description |
Option |
| 1000 |
LANGUAGE |
English |
| 1010 |
APPLICATION |
"residential" or "commercial" |
| 1030 |
THERMOSTAT NAME |
Select Appropriate Name |
| 110 |
SYSTEM ZONING |
Not Zoned |
|
** CONNECT ** |
|
|
EQUIPMENT INTERFACE NAME |
EIM |
|
CONNECT OTHER REDLINK |
No |
| 1040 |
SCHEDULING OPTION |
Programmable |
| 1050 |
TEMPERATURE SCALE |
"fahenheit" |
| 1060 |
OUTDOOR AIR SENSOR |
No (Optional) |
| 2000 |
HEATING SYSTEM |
"heat pump" |
| 2010 |
HEATING EQUIPMENT |
"air to air heat pump" |
| 2060 |
REVERSING VALVE |
"o (o/b on cool)" |
| 2070 |
STAGES |
1, 1 |
| 2180 |
BACKUP HEAT TYPE |
"electric" |
| 3000 |
SYSTEM CHANGEOVER |
"automatic", 3deg |
| 3010 |
CONTROL OPTIONS |
"advanced options" |
| 3021 |
FINISH WITH HIGH HEAT |
No |
| 3090 |
BACKUP HEAT DROOP |
2.0 deg |
| 3110 |
UPSTAGE TIMER BACKUP HT |
Off |
| 3120 |
OUTDOOR TEMP LOCKOUTS |
Off, Off |
| 3140 |
COMPRESSOR CYCLES STG 1 |
3 |
| 3160 |
BACKUP HEAT CYCLES PER HR |
9 |
| 3240 |
COMPRESSOR OFF TIME |
3 minutes |
| 3260 |
EXTENDED FAN RUN TIMES |
60, 60 |
| 4000 |
SCHEDULE PERIODS |
"4 periods per day" |
| 4010 |
PRE-OCCUPANCY PURGE |
Off |
| 4020 |
TYPE OF OVERRIDE |
standard |
| 4030 |
OVERRIDE DURRATION |
4 hours |
| 4050 |
MIN HEAT RECOVERY RATE |
3º/hr |
| 4070 |
MIN COOL RECOVERY RATE |
5º/hr |
| 4090 |
ADAPTIVE RECOVERY |
Yes |
| 4100 |
TEMPERATURE RANGE STOPS |
64 deg, 82 deg |
| 4110 |
KEYPAD LOCKOUT |
"Unlocked" |
| 5000 |
WHAT SENSORS CONNECTED |
None |
| 6000 |
WHAT DRY CONACTS |
None |
| 7000 |
FILTER TYPE |
"media" |
| 7020 |
NUMBER OF AIR FILTERS |
1 |
| 7110 |
AIR FILTER |
"reminder-off" |
| 8000 |
HUMIDIFIER TYPE |
"none" or "bypass-fan/pwrd" |
| 8030 |
HUMIDIFIER WIRING |
"t-stat terminal U1" |
| 8050 |
WINDOW PROTECTION |
Off |
| 8060 |
USE HIMIDIFIER IN HEAT MODE |
Yes |
| 8070 |
HUMIDIFIER CONTROL |
"hum when heat is on" |
| 8100 |
HUMIDIFIER PAD |
"reminder-off" |
| 9000 |
DEHUM EQUIPMENT |
"A/C with high fan" |
| 9070 |
DEHUM OVER COOLING LIMIT |
1 deg |
| 9180 |
DEHUM AWAY MODE |
"not allowed" |
| 9210 |
DEHUMIDIFIER FILTER |
"reminder-off" |
| 10000 |
VENTILATION TYPE |
"none" |
| 10170 |
VENTILATION FILTER |
"reminder-off" |
| 11000 |
NUMBER OF UV DEVICES |
0 |
| 12000 |
CUSTOM REMINDERS |
|
| 14000 |
CLOCK FORMAT |
"12 hour" |
| 14010 |
DAYLIGHT SAVING TIME |
On |
| 14020 |
INDOOR OFFSETs |
0 deg, 0% |
| 15000 |
DEALER INFORMATION |
Name : "GHAC" |
| 15000 |
DEALER INFORMATION |
Phone: 606-836-8143 |
| 15010 |
MORE DEALER INFORMATION |
email: |
| 15010 |
MORE DEALER INFORMATION |
website: www.ghacinc.com |
| 15020 |
DEALER MESSAGE |
|
- Humidifier Options Only
- Commercial Options Only
Step 3: Press "Done"
- "Do you want to exit Installer Setup? Press "Yes"
- "Do you want to save changes?" Press "Yes"
Step 4: Press "HOME" to go back to the Home Screen.