Honeywell Thermostats: Prestige IAQ
Re: Configure 2-Stage Heat, 1-Stage Cool Heat Pump
Step 1: Enter Configuration Screen
First-Time Power-Up → Step 2. Enter Setup Information
Service Configuration ⇒ Go into "Installer Setup"
Step 2: Enter Setup Information below:
Setup# | Description | Option |
1000 | LANGUAGE | English |
1010 | APPLICATION | "residential" or "commercial" |
1030 | THERMOSTAT NAME | Select Appropriate Name |
110 | SYSTEM ZONING | Not Zoned |
** CONNECT ** | ||
EQUIPMENT INTERFACE NAME | EIM | |
CONNECT OTHER REDLINK | No | |
1040 | SCHEDULING OPTION | Programmable |
1050 | TEMPERATURE SCALE | "fahenheit" |
1060 | OUTDOOR AIR SENSOR | No (Optional) |
2000 | HEATING SYSTEM | "heat pump" |
2010 | HEATING EQUIPMENT | "air to air heat pump" |
2060 | REVERSING VALVE | "o (o/b on cool)" |
2070 | STAGES | 1, 1 |
2180 | BACKUP HEAT TYPE | "electric" |
3000 | SYSTEM CHANGEOVER | "automatic", 3deg |
3010 | CONTROL OPTIONS | "advanced options" |
3021 | FINISH WITH HIGH HEAT | No |
3090 | BACKUP HEAT DROOP | 2.0 deg |
3110 | UPSTAGE TIMER BACKUP HT | Off |
3120 | OUTDOOR TEMP LOCKOUTS | Off, Off |
3140 | COMPRESSOR CYCLES STG 1 | 3 |
3160 | BACKUP HEAT CYCLES PER HR | 9 |
3240 | COMPRESSOR OFF TIME | 3 minutes |
3260 | EXTENDED FAN RUN TIMES | 60, 60 |
4000 | SCHEDULE PERIODS | "4 periods per day" |
4010 | PRE-OCCUPANCY PURGE | Off |
4020 | TYPE OF OVERRIDE | standard |
4030 | OVERRIDE DURRATION | 4 hours |
4050 | MIN HEAT RECOVERY RATE | 3º/hr |
4070 | MIN COOL RECOVERY RATE | 5º/hr |
4090 | ADAPTIVE RECOVERY | Yes |
4100 | TEMPERATURE RANGE STOPS | 64 deg, 82 deg |
4110 | KEYPAD LOCKOUT | "Unlocked" |
5000 | WHAT SENSORS CONNECTED | None |
6000 | WHAT DRY CONACTS | None |
7000 | FILTER TYPE | "media" |
7020 | NUMBER OF AIR FILTERS | 1 |
7110 | AIR FILTER | "reminder-off" |
8000 | HUMIDIFIER TYPE | "none" or "bypass-fan/pwrd" |
8030 | HUMIDIFIER WIRING | "t-stat terminal U1" |
8050 | WINDOW PROTECTION | Off |
8060 | USE HIMIDIFIER IN HEAT MODE | Yes |
8070 | HUMIDIFIER CONTROL | "hum when heat is on" |
8100 | HUMIDIFIER PAD | "reminder-off" |
9000 | DEHUM EQUIPMENT | "A/C with high fan" |
9070 | DEHUM OVER COOLING LIMIT | 1 deg |
9180 | DEHUM AWAY MODE | "not allowed" |
9210 | DEHUMIDIFIER FILTER | "reminder-off" |
10000 | VENTILATION TYPE | "none" |
10170 | VENTILATION FILTER | "reminder-off" |
11000 | NUMBER OF UV DEVICES | 0 |
12000 | CUSTOM REMINDERS | |
14000 | CLOCK FORMAT | "12 hour" |
14010 | DAYLIGHT SAVING TIME | On |
14020 | INDOOR OFFSETs | 0 deg, 0% |
15000 | DEALER INFORMATION | Name : "GHAC" |
15000 | DEALER INFORMATION | Phone: 606-836-8143 |
15010 | MORE DEALER INFORMATION | email: |
15010 | MORE DEALER INFORMATION | website: www.ghacinc.com |
15020 | DEALER MESSAGE |
Step 3: Press "Done"
Step 4: Press "HOME" to go back to the Home Screen.