Re: Installer Setup - 3Ht/2Cl Heat Pump

To Enter Installer Setup:

  • From the home screen, press the System key. (Press Done or Cancel key to return to home screen.)
  • Five blank touch keys show on the bottom of the screen between the Done and Cancel keys. Press and hold the two blank keys on either side of the center blank key for approximately five seconds until screen changes.

Setup# Description Values
110 Zone Number
  • 0 = Not Zoned
120 First 2 digits of Year
  • 20
130 Last 2 digits of Year
140 Calendar Month
  • 01 - 12
150 Day of the Month
  • 01 - 31
160

Schedule Options

  • 0=Non-Prog
  • 4=Programmable
165 Energy Start Schedule
  • 0 = No
172 System Type
  • 2=Heat Pump
173 Heat Pump Type
  • 0=Air to Air
174 Compressor Stages
  • 2
176 Conv / Aux Stages
  • 1
190

Reversing Valve

  • 0=Cooling
200

Backup Heat

  • 0=Electric
210 Fossil Fuel Control
  • 1=External control
220 Compressor 1 CPH
  • 3
230 Compressor 2 CPH
  • 3
240

Heat 1 Cycles/Hr

  • 6
280 Backlight
  • 1=Continuous
290

Additional Choices

  • 1=All Choices
300

Changeover Type

  • 1=Automatic
310 Changeover Deadband
  • 3
320 Temperature Scale
  • 0=Farenheit
330 Daylight Savings
  • 2=New Dates
340 Remote Temperature
  • 0=None
342 Outdoor Temperature
  • 0=None
350 Compressor Lockout
  • 10
360 Aux Heat Lockout
  • 50
365 Discharge Temp Sensor
  • E=Auto Discover
370 Humidity Sensor
  • 1=Internal
372 Humidification
  • 1=Humidify (no frost control)
374 Humidify Fan Action
  • 0=Humidify w/ Fan or Heat
379 Dehumidify Control
  • 1=Dehumidify w/ A/C
382 Dehumidify Modes
  • 0=Dehum in Cool or Auto
383 Dehum Over-Cool Limit
  • 1 Deg.
384 Dehumidify Fan Action
  • 1=No Action
390 Dehumidify Away Mode
  • 0=Disabled
400 Ventilation Control
  • 0=None
500 Filter Reminder
  • 0=Off
510

Humidifier Reminder

  • 0=Off
520

UV Reminder

  • 0=Off
530 Intelligent Recovery
  • 1=On
540

Programmable Periods

  • 2 or 4
550 # of Weekend Periods
  • 4
560 # of Weekday Periods
  • 4
580 Compressor Delay
  • 3
600 Highest Heat Temp
  • 82
610 Lowest Cool Temp
  • 65
640 Clock Format
  • 12=12 Hour
650 Extend Fan Time (Heat)
  • 0
660

Extend Fan Time (Cool)

  • 0
670 Keypad Lockout
  • 0=Unlocked
680 Temperature Control (Heat)
  • 2=Standard
690 Temperature Control (Cool)
  • 2=Standard
700 Temperature Display Offset
  • 0
701 Humidity Display Offset
  • 0
710 Thermostat Reset
  • 0=No reset
This article was:   Helpful | Not helpful