Knowledgebase

T4 Pro - Installer Setup options

Article ID: 312
Last updated: 15 Aug, 2017

Honeywell Thermostat: TH4110U T4 Pro

Re: Installer Setup Options

To enter Installer Setup:

  • Press and hold the "Center" button and the "+" button together for 3 seconds.
  • Press "Select" to enter Setup.
  • Press "Select" to cycle through setup options.
  • Press "+" or "-" to change values.
  • Press "Select" to confirm changes or "Back" to ignore changes.
  • To Finish and Save changes, press "Home".

Setup# Function Options
120 Schedule Options
  • 0 = Non-Programmable
  • 2 = 5/2 Programmable
  • 3 = 5/1/1 Programmable
  • 4 = 7 Day Programmable
125 Temperature Scale
  • 0 = Farenheit
  • 1 = Celsius
200

Heat Equipment

  • 1 = Conventional
  • 2 = Heat Pump
  • 3 = Radiant Heat
  • 5 = None (Cool Only)
205 Heat Type
  • 1 = Standard Eff Gas
  • 2 = High Eff Gas
  • 3 = Oil Furnace
  • 4 = Electric Furnace
  • 7 = Air to Air Heat Pump
  • 8 = Geothermal Heat Pump
  • 9 = Hot Water Radiant
  • 12 = Steam 
218 Reversing Valve
  • 0 = O/B Energizes in Cool
  • 1 = O/B Energizes in Heat
220 Cool Stages
  • 0 or 1
221 Heat/Backup Stages
  • 1
230 Heat Fan Control
  • 1 = Equipment Controls Fan
  • 2 = Thermostat Controls Fan
300 System Changeover
  • 0 = Manual
  • 1 = Automatic
303 Auto Changeover Differential
  • 0 to 5 Deg F.
365 Cool 1 Cycle Rate
  • 1 to 6
370 Heat 1 Cycle Rate
  • 1 to 12
370 Aux Ht Cycle Rate
  • 1 to 12
387 Short-Cycle Time
  • 0 = Off
  • 1 to 5 Min
425 Intelligent Recovery
  • 0 = No
  • 1 = Yes
430 Min Cool Setpt
  • 50 to 99 Deg F.
431 Max Heat Setpt
  • 45 to 90 Deg F.
435 Keypad Lockout
  • 0 = None
  • 1 = Partial
  • 2 = Full
702 Air Filter Qty
  • 0 to 2
711 Filter 1 Timer
  • 0 = Off
  • 1 = 10 Run Days
  • 2 = 20 Run Days
  • 3 = 30 Run Days
  • 4 = 45 Run Days
  • 5 = 60 Run Days
  • 6 = 90 Run Days
  • 7 = 120 Run Days
  • 8 = 150 Run Days
  • 9 = 30 Calendar Days
  • 10 = 45 Calendar Days
  • 11 = 60 Calendar Days
  • 12 = 75 Calendar Days
  • 13 = 3 Calendar Months
  • 14 = 4 Calendar Months
  • 15 = 5 Calendar Months
  • 16 = 6 Calendar Months
  • 17 = 9 Calendar Months
  • 18 = 12 Calendar Months
  • 19 = 15 Calendar Months
712 Filter 2 Timer
  • 0 = Off
  • 1 = 10 Run Days
  • 2 = 20 Run Days
  • 3 = 30 Run Days
  • 4 = 45 Run Days
  • 5 = 60 Run Days
  • 6 = 90 Run Days
  • 7 = 120 Run Days
  • 8 = 150 Run Days
  • 9 = 30 Calendar Days
  • 10 = 45 Calendar Days
  • 11 = 60 Calendar Days
  • 12 = 75 Calendar Days
  • 13 = 3 Calendar Months
  • 14 = 4 Calendar Months
  • 15 = 5 Calendar Months
  • 16 = 6 Calendar Months
  • 17 = 9 Calendar Months
  • 18 = 12 Calendar Months
  • 19 = 15 Calendar Months
1400 Backlight
  • 0 = On Demand
  • 1 = Continuous
1401 Brightness
  • 1 to 5
1410 Clock
  • 12
  • 24
1415 Daylight Savings
  • 0 = Off
  • 1 = On
1420 Temperature Offset
  • -3 to +3 Deg F.