Knowledgebase

T6 Pro Wi-Fi Setup Options

Article ID: 790
Last updated: 19 Jan, 2026

Honeywell Thermostat: TH6320WF T6 Pro Wi-Fi

Re: Installer Setup Options

To enter Installer Setup:

  • Press and hold the "MENU" button for 5 seconds.
  • Press "Select" to enter Setup.
  • Press "Select" to cycle through setup options.
  • Press "+" or "-" to change values.
  • Press "Select" to confirm changes or "Back" to ignore changes.
  • To Finish and Save changes, press "Home".

Setup# Function Options
120 Schedule Options
  • No Schedule
  • MO-SUN (Every Day the same)
  • MO-FRI, SA, SU (Mon-Fri same, Sat & Sun separate)
  • MO-FRI, SA-SU (Mon-Fri same, Sat-Sun same)
  • Every Day (Each day separate)
125 Temperature Scale
  • Farenheit
  • Celsius
130

Outdoor Sensor

  • No
  • Wired
  • Internet
200

Heat Equipment

  • Conventional
  • Heat Pump
  • Boiler
  • Cool Only
205 Heat Type Conventional Forced Air Heat:
Standard Gas (STD GAS), High Efficiency Gas (EFF GAS),
Oil, Electric, Fan Coil
Heat Pump:
Air To Air, Geothermal
Boiler:
Hot Water, Steam
218 Reversing Valve
  • O/B Energizes in Cool
  • O/B Energizes in Heat
220 Cool Stages
  • 0, 1 or 2
221 Heat/Backup Stages
  • Heat Stages = 0, 1 or 2 
  • Aux Heat Stages = 0 or 1
230 Heat Fan Control
  • Equipment Controls Fan
  • Thermostat Controls Fan
253 Aux/E Control
  • Aux & E Together
  • Aux & E Separate
255 Aux Heat Type
  • Electric Furnace
  • Gas Furnace
256 Em Heat Type
  • Electric Furnace
  • Gas Furnace
260 Fossil Fuel Control
  • Thermostat Controls 
  • External Fossil Fuel Kit
300 Auto Changeover
  • On
  • Off
303 Auto Changeover Differential
  • 0 to 5 Deg F.
305 High Cool Finish
  • Yes
  • No
306 High Heat Finish
  • Yes
  • No
340 Aux Heat Droop
  • 0 = Comfort
  • 2 to 15 Deg F.
350 Aux Ht Upstage Timer
  • 0 = Off
  • 1 = 30 Min
  • 2 = 45 Min
  • 3 = 60 Min
  • 4 = 75 Min
  • 5 = 90 Min
  • 6 = 2 Hrs
  • 7 = 3 Hrs
  • 8 = 4 Hrs
  • 10 = 5 Hrs
355 Compressor Lockout
  • Off
  • 5 to 60 Deg F (5 Deg Increments)
356 Aux Heat Lockout
  • Off
  • 5 to 65 Deg F (5 Deg Increments)
365 Cool 1 Cycle Rate
  • 1 to 6
366 Cool 2 Cycle Rate
  • 1 to 6
370 Heat 1 Cycle Rate
  • 1 to 12
371 Heat 2 Cycle Rate
  • 1 to 12
375 Aux Ht Cycle Rate
  • 1 to 12
378 Em Ht Cycle Rate
  • 1 to 12
387 Comp Short-Cycle Time
  • Off
  • 1 to 5 Min
390 Extended Fan in Cool
  • Off, 30, 60 or 90 Sec
  • 2 to 15 Min
391 Extended Fan in Heat
  • Off, 30, 60 or 90 Sec
  • 2 to 15 Min
425 Intelligent Recovery
  • On
  • Off
429 Max Cool Setpt
  • 50 to 99 Deg F.
430 Min Cool Setpt
  • 50 to 99 Deg F.
431 Max Heat Setpt
  • 45 to 90 Deg F.
432 Min Heat Setpt
  • 45 to 90 Deg F.
435 Keypad Lockout
  • None
  • Partial
  • Full
500 Wired Indoor Sensor
  • No
  • Yes
515 Sensor Type
  • 10k
  • 20k
520 Sensor Control
  • Thermostat
  • Wired
  • Average
702 Air Filter Qty
  • 0 to 2
711 Filter 1 Timer
  • Off
  • 10 Run Days
  • 20 Run Days
  • 30 Run Days
  • 45 Run Days
  • 60 Run Days
  • 90 Run Days
  • 120 Run Days
  • 150 Run Days
  • 30 Calendar Days
  • 45 Calendar Days
  • 60 Calendar Days
  • 75 Calendar Days
  • 3 Calendar Months
  • 4 Calendar Months
  • 5 Calendar Months
  • 6 Calendar Months
  • 9 Calendar Months
  • 12 Calendar Months
  • 15 Calendar Months
712 Filter 2 Timer
  • Off
  • 10 Run Days
  • 20 Run Days
  • 30 Run Days
  • 45 Run Days
  • 60 Run Days
  • 90 Run Days
  • 120 Run Days
  • 150 Run Days
  • 30 Calendar Days
  • 45 Calendar Days
  • 60 Calendar Days
  • 75 Calendar Days
  • 3 Calendar Months
  • 4 Calendar Months
  • 5 Calendar Months
  • 6 Calendar Months
  • 9 Calendar Months
  • 12 Calendar Months
  • 15 Calendar Months
810 Hum Pad Reminder
  • Off
  • 6 Months
  • 12 Months
921 Dehum Filter Reminder
  • Off
  • 30, 60 Calendar Days
  • 3-12 Calendar Months
1000 Vent Type
  • None
  • ERV/HRV
  • Passive
  • Fresh Air Damper
1005 Vent Method
  • ASHRAE 2013
  • ASHRAE 2010
  • Percent Time
  • Fresh Air Damper
1006 Vent Fan Control
  • Thermostat
  • Equipment
1007 Bedrooms
  • 1, 2, 3, 4, 5, 6
1008 Home Size
  • 1000 - 5000 sq. ft.
1009 Vent Rate
  • 30 - 350 cfm
1011 Vent Percent Time
  • 10 - 100%
1012 Vent Priority
  • Lockouts
  • ASHRAE
1013 Low OD Temp Vent Lockout
  • Off
  • -20 to -40 Deg F.
1014 High OD Temp Vent Lockout
  • Off
  • 80 to 110 Deg F.
1015 High Dew Pt Vent Lockout
  • Off
  • 65 to 85 Deg F.
1017 Vent Core Reminder
  • Off, 3, 6, 9, 12 Months
1018 Vent Filter Reminder
  • Off, 3, 6, 9, 12 Months
1100 UV Devices
  • 0 - 2
1105 UV Bulb 1 Reminder
  • Off, 6, 12, 24 Months
1106 UV Bulb 2 Reminder
  • Off, 6, 12, 24 Months
1401 Brightness
  • 0 = Off
  • 1 to 5
1410 Clock
  • 12 hour
  • 24 hour
1415 Daylight Savings
  • On
  • Off
1420 Temperature Offset
  • Off
  • -3 to +3 Deg F.