Honeywell Thermostats: TH8320R & TH8321R
Re: Configure the thermostat for Add-On Heat Pump
Step 1: Go to "Installer Setup"
- From the HOME Screen press the MENU tab
- Scroll down and select "Installer Options"
- Enter the Factory Password
- Select "Installer Setup"
Step 2: Enter Setup Information below:
Setup# |
Description |
Option |
101 |
APPLICATION |
"residential" or "commercial" |
103 |
THERMOSTAT NAME |
Select Appropriate Name |
104 |
THERMOSTAT TYPE |
"programmable" |
105 |
TEMPERATURE SCALE |
"farenheit" |
106 |
OUTDOOR AIR SENSOR |
"yes" |
200 |
HEATING SYSTEM |
"heat pump" |
201 |
HEATING EQUIPMENT |
"air to air heat pump" |
206 |
REVERSING VALVE |
"o (o/b on cool)" |
207 |
COMPRESSOR STAGES |
1 |
207 |
BACKUP HEAT STAGES |
1 |
218 |
BACKUP HEAT TYPE |
"gas/oil" |
219 |
EXTERNAL FOSSIL FUEL KIT |
"no" |
300 |
SYSTEM CHANGEOVER |
"automatic" |
300 |
AUTO CHANGE DEADBAND |
3 |
301 |
CONTROL OPTIONS |
"advanced options" |
302 |
FINISH WITH HIGH HEAT |
Yes |
309 |
BACKUP HEAT DROOP |
2.0 deg |
311 |
UPSTAGE TIMER BACKUP HT |
Off |
312 |
OUTDOOR LOCKOUT H/P |
40 deg |
312 |
O/D LOCKOUT BACKUP HEAT |
Off |
314 |
COMPRESSOR CYCLES STG 1 |
3 |
316 |
BACKUP HEAT CYCLES PER HR |
5 |
324 |
COMPRESSOR OFF TIME |
3 minutes |
326 |
EXTENDED FAN RUN IN COOL |
Off |
326 |
EXTENDED FAN RUN IN HEAT |
Off |
400 |
SCHEDULE PERIODS |
"4 periods per day" |
401 |
PRE-OCCUPANCY PURGE |
Off |
402 |
TYPE OF OVERRIDE |
standard |
403 |
OVERRIDE DURRATION |
4 hours |
405 |
MIN HEAT RECOVERY RATE |
3º/hr |
407 |
MIN COOL RECOVERY RATE |
5º/hr |
409 |
ADAPTIVE RECOVERY |
Yes |
410 |
MINIMUM COOL SETPOINT |
64 deg |
410 |
MAXIMUM HEAT SETPOINT |
82 deg |
411 |
KEYPAD LOCKOUT |
"Unlocked" |
500 |
WIRED SENSOR ON S TERMINAL |
yes |
500 |
WIRED INDOOR SENSOR |
no |
500 |
WIRED OUTDOOR SENSOR |
yes |
505 |
OUTDOOR SENSOR |
tstat terminal S1 |
505 |
OUTDOOR SENSOR |
eim terminal S1 |
500 |
WIRED RETURN AIR SENSOR |
no |
500 |
WIRED DISCHARGE AIR SENSOR |
no |
600 |
DRY CONTACT ON S TERMINAL |
no |
700 |
FILTER TYPE |
"media" |
702 |
NUMBER OF AIR FILTERS |
1 |
711 |
AIR FILTER |
"reminder-off" |
800 |
HUMIDIFIER TYPE |
"none" or "bypass-fan/pwrd" |
803 |
HUMIDIFIER WIRING |
"t-stat terminal U1" |
805 |
WINDOW PROTECTION |
Off |
806 |
USE HIMIDIFIER IN HEAT MODE |
Yes |
806 |
USE HUMIDIFIER IN OFF MODE |
No |
807 |
HUMIDIFIER CONTROL |
"hum when heat is on" |
810 |
HUMIDIFIER PAD |
"reminder-off" |
900 |
DEHUM EQUIPMENT |
"A/C with high fan" |
907 |
DEHUM OVER COOLING LIMIT |
1 deg |
918 |
DEHUM AWAY MODE |
"not allowed" |
921 |
DEHUMIDIFIER FILTER |
"reminder-off" |
1000 |
VENTILATION TYPE |
"none" |
1017 |
VENTILATION FILTER |
"reminder-off" |
1100 |
NUMBER OF UV DEVICES |
0 |
1200 |
CUSTOM REMINDERS |
|
28 |
BACKLIGHTING |
"continuous" |
1400 |
CLOCK FORMAT |
"12 hour" |
1401 |
DAYLIGHT SAVING TIME |
On |
1402 |
INDOOR TEMPERATURE OFFSET |
0 deg |
1402 |
INDOOR HUMIDITY OFFSET |
0% |
1404 |
ALERT LIGHT INDICATOR |
On |
1500 |
DEALER NAME |
"GHAC, INC" |
1500 |
DEALER PHONE |
606-836-8143 |
1501 |
DEALER EMAIL |
service@ghacinc.com |
1501 |
DEALER WEBSITE |
www.ghacinc.com |
1502 |
DEALER MESSAGE |
|
- TH8321R Options Only
- Commercial Options Only
- EIM Options Only
Step 3: Press "Done"
- "Do you want to exit Installer Setup? Press "Yes"
- "Do you want to save changes?" Press "Yes"
Step 4: Press "HOME" to go back to the Home Screen.