Knowledgebase

TH5320R - Setup Options

Article ID: 673
Last updated: 6 Feb, 2023

Honeywell Thermostat: TH5320R Wireless FocusPro

Re: Installer Setup Options

To enter Installer Setup, press and hold the "Fan" button and the "Up" button together until the display changes.

Setup# Function Options
0 Zone Number
  • 0 = Leave at "0"
1 System Type
  • 0 = Gas, oil or electric heat with air conditioning
  • 1 = 1 heat/1 cool heat pump
  • 2 = Heat only (2-wire systems/power to open & close zone valves/normally open zone valves)
  • 3 = Heat only with fan
  • 4 = Cool only
  • 5 = 2 heat/1 cool heat pump
  • 6 = 2 heat/2 cool conventional
  • 7 = 2 heat/1 cool conventional
  • 8 = 1 heat/2 cool conventional
  • 9 = 2 heat/2 cool heat pump
  • 10 = 3 heat/2 cool heat pump
2 Rev Valve
  • 0 = Changeover valve (O/B terminal energized in cooling)
  • 1 = Changeover valve (O/B terminal energized in heating)
3

Fan Control

  • 0 = Gas or oil furnace — equipment controls fan in heating
  • 1 = Electric furnace — thermostat controls fan in heating
4
5

Heat Cycle Rate

  • 5 = For gas or oil furnaces of less than 90%efficiency
  • 1 = For steam or gravity systems
  • 3 = For hot water systems & furnaces of over 90% efficiency
  • 9 = For electric furnaces
  • [Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]
6 2nd Stg Ht Cycle Rate
  • 5 = For gas or oil furnaces of less than 90%efficiency
  • 1 = For steam or gravity systems
  • 3 = For hot water systems & furnaces of over 90% efficiency
  • 9 = For electric furnaces
  • [Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]
7 3rd Stg Ht Cycle Rate
  • 5 = For gas or oil furnaces of less than 90%efficiency
  • 1 = For steam or gravity systems
  • 3 = For hot water systems & furnaces of over 90% efficiency
  • 9 = For electric furnaces
  • [Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]
8 Em Ht Cycle Rate
  • 5 = For gas or oil furnaces of less than 90%efficiency
  • 1 = For steam or gravity systems
  • 3 = For hot water systems & furnaces of over 90% efficiency
  • 9 = For electric furnaces
  • [Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]
9 Compressor Cycle Rate
  • 3 = Recommended for most compressors
  • [Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
10 2nd Stg Cycle Rate
  • 3 = Recommended for most compressors
  • [Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
11
12 Changeover Type
  • 0 = Manual changeover (Heat/Cool/Off)
  • 1 = Auto changeover (Heat/Cool/Auto/Off)
  • 2 = Auto changeover only (Auto)
14 Temperature Display
  • 0 = Fahrenheit
  • 1 = Celsius
15 Compressor Off Delay
  • 5 = Five-minute compressor off time
  • [Other options: 0, 1, 2, 3 or 4-minute off time]
22
26

Aux Heat Control

  • 0 = Comfort
  • 1 = Economy
27

Heat Stop

  • 90 = Highest heating temperature setting
  • 40-89 Heating temperature range (increments of 1°F, or 0.5°C)
28

Cool Stop

  • 50 = Lowest cooling temperature setting
  • 51-99 Cooling temperature range (increments of 1°F, or 0.5°C)
32

Indoor Temp Display Offset

  • 0 = No offset
  • -3 to +3 adjust the displayed temperature up or down (increments of 1°F, or 0.5°C)
33

Outdoor Temp Display Offset

  • 0 = No offset
  • -5 to +5 adjust the displayed temperature up or down (increments of 1°F, or 0.5°C)
35

Humidity Display Offset

  • 0 = -15%
  • 1 = -10%
  • 2 = -5%
  • 3 = No Offset
  • 4 = +5%
  • 5 = +10%
  • 6 = +15%
36

Thermostat Name

  • 52 = Thermostat
39

Wireless Setup

  • 0 = Disconnect thermostat from wireless system
  • 1 = Thermostat is connected
90

Reset

  • 0 = No reset
  • 1 = Reset thermostat back to factory configuration
This article was:   Helpful | Not helpful
Report an issue
Article ID: 673
Last updated: 6 Feb, 2023
Revision: 5
Access: Public
Views: 586
Comments: 0