KN-COB-DP2 Detector Alarm Indicators

Article ID: 624
Last updated: 24 Feb, 2020

Product: KN-COB-DP2 CO Detector

Topic: Alarm Indicators

The KN-COB-DP2 Kiddie CO Detector has both an LED Light and an Audible Alert to indicate the unit status.

Function LED Display Alarm Sound Status Recommendation
Normal Green LED On None Normal AC operation with a good battery None
Normal Green LED Flashes every 60 seconds None Operating on battery power only Plug detector into 120V
Carbon Monoxide Alarm Red LED Flashes with beeps 4 quick beeps every 5 seconds Carbon Monoxide Detected! See "Alarm Action" below!
Low Battery Red LED Flashes every 60 seconds 1 quick beep every 60 seconds Battery Low Replace 2 AA batteries
Error/Service Red LED Flashes every 30 seconds 1 quick beep every 30 seconds Unit is in error condition Replace batteries, if continues, replace detector
Error Red LED On Constant Constant alarm Very low batteries or Unit malfunction Replace batteries, if continues, replace detector
Test/Reset Red LED Flashes with beeps 4 quick beeps Normal Test pattern Unit OK, No CO detected
Event Memory Green LED Flashes every 10 seconds None 100ppm previously detected Push button to clear and test device
Tamper Resist Red LED On Constant Constant after 2 minutes Device unplugged from outlet Plug detector into 120V outlet
End-of-Life Red LED Flashes 2x every 30 seconds 2 quick beeps every 30 seconds End of unit life Replace detector

Alarm Action

If the alarm is sounding, press the test/reset button to terminate the alarm.

  • If the alarm sounds again within 24 hours,
    • Contact a heating professional to check the detector and your appliances.
  • If the unit alarms again within six minutes, it is sensing high levels of CO which can quickly become a dangerous situation. 
    • Immediately move to fresh air - outdoors or by an open door/window.
    • Do a head count to check that all persons are accounted for.
    • Call 911 to report the condition.
    • Do not re-enter the premises until the emergency service responders have arrived, the premises have been aired out, and your alarm remains in its normal condition.