GMS9/GCS9 - Flashing Code 4

Goodman Gas Furnace: GMS9/GCS9

Re: Flashing Code 4

(Assuming original control board)

Code 4 = Limit Circuit Open

If the Limit Circuit opens, the burners will be de-energized and the air circulation and vent blower will be turned on until the Limit Circuit closes. The diagnostic light code for this is four short flashes followed by a pause.

► The diagnostic code will go away once the Limit Circuit closes (not a Hard Lockout).


Qty Possible Causes:
1 Bad Blower Motor / Capacitor
Dirty Air Filter
Bad Control Board
Clogged Evaporator Coil
Under-sized Ductwork
High Gas Pressure
Bad Limit
Blower Speed too Low


CHECKOUT:

1. Check Blower Operation


2. Check Control Board


3. Check Limits


4. Check Temperature Rise


5. Check Air Filter


6. Check Gas Pressure


7. Check Blower Speed


8. Check Duct Static Pressure



Article ID: 662
Last updated: 16 Dec, 2020
Revision: 9
Equipment -> Gas Furnaces -> Goodman -> GMS9\GCS9 -> GMS9/GCS9 - Flashing Code 4