Carrier Mini-Splits: 38 - 40GVQ
Re: Error Codes
ERROR CODES AT INDOOR UNIT | |
CODE | DESCRIPTION |
EE | Indoor PCB Malfunction. Replace indoor main board. |
E2 | Anti-freeze Protection. Outdoor ambient temperature is too low. |
E4 | Discharge temperature sensor out of range. |
E5 | Low voltage protection |
E6 | Communication malfunction |
E8 | System overload protection |
U8 | Indoor board malfunction |
H6 | Indoor motor malfunction |
C5 | Missing jumper from indoor board |
F1 | Return air temperature sensor malfunction |
F2 | Indoor pipe temperature sensor malfunction |
F3 | Outdoor ambient temperature sensor malfunction |
F4 | Condenser temperature sensor malfunction (open or shorted) |
F5 | Discharge temperature sensor malfunction (open or shorted) |
F6 | Overload limit, compressor speed reduction |
F8 | Over current compressor speed reduction |
F9 | Compressor discharge temperature high, compressor speed reduction |
PH | Over voltage protection |
U5 | Current detection malfunction |
P5 | Compressor current protection |
H1 | Defrosting |
H3 | Compressor overload protection |
H4 | System overload protection |
H5 | IPM protection |
HC | PFC (power factor correction) board protection |
H7 | Compressor speed reduction |
H0 | Ambient temperature cut off range |
LC | Compressor start-up failure |
U1 | Compressor phase detection error |