PT9 - Flashing Code 3

York Gas Furnace: PT9

Re: Flashing Code 3

Code 3 = The 1LP pressure switch contact did not close during 1st stg heat operation, or the 2LP pressure switch contact did not close during 2nd stg heat operation

► The 1LP switch is typically rated for 0.75" w.c. and the 2LP switch is typically rated for 1.25." w.c.

► Both switches are 2-port (negative port from the inducer, positive to the enclosed burner box).


Qty Possible Causes:
1 Bad Inducer Motor
1 Item Stuck in Inducer
Water in Vent
Restricted Intake
Clogged Drain/Trap
Bad Pressure Switch


CHECKOUT:

1. Check Inducer Motor Operation


2. Check Pressure Switches


3. Check Condensate Drainage



Article ID: 493