TG9S/GY9S - Flashing Code 3

York 90% Gas Furnace: TG9S

Re: Flashing Code 3

Code 3 = Furnace Pressure Switch failed to close on a call for heat.

►The code description on the blower door says, "Vent or Termination Problem" which is a possible cause, but not the most likely.


This gas furnace has two pressure switches:

Either switch open after the inducer motor is commanded to start will generate a Code 3.


Qty Possible Causes:
11 Bad Inducer Motor
4 Water in inducer 
2 Clogged or Restricted Vent
3 Bad Vent Pressure Switch
4 Bad Drain Pressure Switch
3 Clogged / Frozen Drain
3 Pressure Hose Problem
Item Stuck in Inducer Motor
Bad Ignition Control


CHECKOUT:

1. Check Control Board


2. Check Inducer


3. Check Pressure Switches


4. Check Condensate Drainage