        <title>TM9T - Flashing Code 6</title>
        <link>https://ghac.makekb.com/entry/390/</link>
        <description>York Gas Furnace: TM9T   Re: Flashing Code 6   Code 6 = Pressure switch opened (Code 3) 4 times during a run cycle.   ► This is a &quot;Soft Lockout&quot; which will automatically reset after 1 hour.   ► There are 3 pressure switches on this furnace. 1LP...</description>
		<category></category>
		<pubDate>Tue, 07 Apr 2026 16:36:00 +0000</pubDate>
    </item>
    
    <item>
        <title>TG9S/GY9S - Flashing Code 11</title>
        <link>https://ghac.makekb.com/entry/483/</link>
        <description>York Gas Furnace: TG9S/GY9S   Re: Flashing Code 11   This indicates that a primary or auxiliary limit switch has opened and has remained open for more than five minutes. This condition is usually associated with an air circulation failure.    ►...</description>
		<category></category>
		<pubDate>Tue, 07 Apr 2026 14:34:07 +0000</pubDate>
    </item>
    
    <item>
        <title>T6 Pro - Add-On Heat Pump Setup</title>
        <link>https://ghac.makekb.com/entry/735/</link>
        <description>Honeywell Thermostat: TH6220U/TH6320U T6 Pro   Re: Add-On Heat Pump Setup   To enter Installer Setup:    Press and hold the &quot;Center&quot; button and the &quot;+&quot; button together for 3 seconds.  Press &quot;Select&quot; to enter Setup.  Press &quot;Select&quot; to cycle through...</description>
		<category></category>
		<pubDate>Thu, 12 Mar 2026 18:09:30 +0000</pubDate>
    </item>
    
    <item>
        <title>PHU - Flashing Code 7</title>
        <link>https://ghac.makekb.com/entry/398/</link>
        <description>York Gas Furnace: PHU   Re: No Heat - Code 7   Code 7 = Failure to Sense Flame          Qty   Possible Causes:       7   Dirty Flame Sensor       7   Bad Glow Plug       1   Clogged Burners       1   Bad Gas Valve          No or Low Gas Pressure   ...</description>
		<category></category>
		<pubDate>Thu, 12 Mar 2026 17:57:22 +0000</pubDate>
    </item>
    
    <item>
        <title>P3UR - Flashing Code 3</title>
        <link>https://ghac.makekb.com/entry/516/</link>
        <description>York 90% Gas Furnace: P3UR  Re: Flashing Code 3  Code 3 = Furnace Pressure Switch failed to close on a call for heat.          Qty   Possible Causes:       2   Bad Inducer Motor       1   Bad Pressure Switch       1   Clogged / Frozen Drain       1 ...</description>
		<category></category>
		<pubDate>Mon, 23 Feb 2026 16:46:52 +0000</pubDate>
    </item>
    
    <item>
        <title>G6RC - Flashing Code 1</title>
        <link>https://ghac.makekb.com/entry/788/</link>
        <description>Nordyne Gas Furnace: G6RC   Re: Flashing Code 1   Code 1 = Limit switch open   If the limit control opens, the burners will be de-energized and the air circulation and vent blower will be turned on until the limit closes.    The diagnostic light...</description>
		<category></category>
		<pubDate>Thu, 12 Feb 2026 16:07:48 +0000</pubDate>
    </item>
    
    <item>
        <title>GULA - Flashing Code 4</title>
        <link>https://ghac.makekb.com/entry/688/</link>
        <description>Amana Gas Furnace: GULA  Re: Flashing Code 4  Code 4 = Main limit switch (auto-reset) has opened its normally closed contacts, or the Blower Auxiliary Limit (manual-reset) has tripped.    The control will operate the supply air blower and inducer...</description>
		<category></category>
		<pubDate>Tue, 10 Feb 2026 14:22:28 +0000</pubDate>
    </item>
    
    <item>
        <title>TG9S/GY9S - Flashing Code 4</title>
        <link>https://ghac.makekb.com/entry/478/</link>
        <description>York Gas Furnace: TG9S/GY9S   Re: Flashing Code 4   Code 4 has two possible meanings:    Code 4 = Limit switch circuit is currently open.      If the limit switch circuit opens during a call for heat, the control will indicate 4 Red Flashes.   ►...</description>
		<category></category>
		<pubDate>Mon, 09 Feb 2026 14:38:14 +0000</pubDate>
    </item>
    
    <item>
        <title>TG9S/GY9S - Flashing Code 7</title>
        <link>https://ghac.makekb.com/entry/474/</link>
        <description>York Gas Furnace: TG9S/GY9S   Re: No Heat - Flashing Code 7   Code 7 = Three consecutive failed ignition attempts (failed to sense flame).    ► This is a &quot;Soft-Lockout&quot; which will automatically reset/retry after 1 hour.         Qty   Possible...</description>
		<category></category>
		<pubDate>Mon, 02 Feb 2026 22:32:04 +0000</pubDate>
    </item>
    
    <item>
        <title>TM9Y - Flashing Code 4</title>
        <link>https://ghac.makekb.com/entry/386/</link>
        <description>York Gas Furnace: TM9Y   Re: Flashing Code 4   Code 4 has two possible meanings:    Code 4 = Limit switch circuit is currently open.      If the limit switch circuit opens during a call for heat, the control will indicate 4 Red Flashes.   ► The...</description>
		<category></category>
		<pubDate>Sun, 01 Feb 2026 20:47:31 +0000</pubDate>
    </item>
    
    <item>
        <title>GY8S -Flashing Code 7</title>
        <link>https://ghac.makekb.com/entry/374/</link>
        <description>York 80% Gas Furnace: GY8S   Re: Flashing Code 7 / Error Code 7   Flashing Code 7 = Lockout due to ignition retries. Caused by multiple failed ignition attempts.   ► Code 7 is a Hard Lockout that disables heat operation and must be reset by cycling...</description>
		<category></category>
		<pubDate>Fri, 30 Jan 2026 14:22:49 +0000</pubDate>
    </item>
    
    <item>
        <title>Y81E/Y91E - Flashing Code 4</title>
        <link>https://ghac.makekb.com/entry/756/</link>
        <description>York Gas Furnace: Y81E/Y91E  Re: Flashing Code 4  Code 4 = Main limit switch has opened its normally closed contacts.    The control will operate the supply air blower and inducer while the open limit condition exists.   ► If the main limit switch...</description>
		<category></category>
		<pubDate>Wed, 21 Jan 2026 18:37:13 +0000</pubDate>
    </item>
    
    <item>
        <title>T6 Pro Wi-Fi Setup Options</title>
        <link>https://ghac.makekb.com/entry/790/</link>
        <description>Honeywell Thermostat: TH6320WF T6 Pro Wi-Fi   Re: Installer Setup Options   To enter Installer Setup:    Press and hold the &quot;MENU&quot; button for 5 seconds.  Press &quot;Select&quot; to enter Setup.  Press &quot;Select&quot; to cycle through setup options.  Press &quot;+&quot; or...</description>
		<category></category>
		<pubDate>Mon, 19 Jan 2026 19:45:20 +0000</pubDate>
    </item>
    
    <item>
        <title>GMH95 / GCH95 - Flashing Code 4</title>
        <link>https://ghac.makekb.com/entry/683/</link>
        <description>Goodman Gas Furnace: GMH95/ GCH95  Re: Flashing Code 4  Code 4 = Main limit switch (auto-reset) has opened its normally closed contacts, or the Blower Auxiliary Limit (manual-reset) has tripped.    The control will operate the supply air blower and...</description>
		<category></category>
		<pubDate>Tue, 13 Jan 2026 18:00:51 +0000</pubDate>