G6RC - Flashing Code 1

Nordyne Gas Furnace: G6RC

Re: Flashing Code 1

Code 1 = Limit switch open

If the limit control opens, the burners will be de-energized and the air circulation and vent blower will be turned on until the limit closes.

The diagnostic light code for this is one short flash followed by a pause.

► All limits are wire in series (Primary Limit, Manual-Reset Vent Limit, Manual-Reset Flame Rollout(s), Manual-Reset Blower Limit).


Qty Possible Causes:
2 Dirty/Restrictive Air Filter
Clogged Evaporator Coil
1 Clogged Recoup Coil/Blower Wheel
2 Under-Sized/Restricted Ductwork
3 High Gas Pressure
Bad Limit
Blower Speed too Low


CHECKOUT:

1. Check the Limit Circuit


2. Check Temperature Rise


3. Check Air Filter


4. Check Gas Pressure


5. Check Blower Speed


6. Check Duct Static Pressure