GM9S96 - FLASHING EE0

Goodman Gas Furnace: GM9S96

Re: Flashing Code EE0/ Won't Ignite

EE0 = 3 Failed Ignition Attempts

► Be aware that the furnace Condensate Pressure Switch (Front Cover Pressure Switch) breaks power to the gas valve and will cause an EE0 Code (Does not cause a pressure switch code).


Qty Possible Causes:
Dirty Flame Sensor
Bad Ignitor
Bad Control Board
1 Clogged Drain 
1 Bad "Front Cover" Pressure Switch 
Tripped Auxiliary Limit
Bad Gas Valve


CHECKOUT:

1. Check Ignition Sequence


2. Check Glow Plug


3. Check Ignition


4. Check Control Board Output


5. Check Gas Pressure / Valve


6. Check Flame Sensor


7. Check Furnace Drains



Article ID: 786
Last updated: 16 Dec, 2025
Revision: 6
Equipment -> Gas Furnaces -> Goodman -> GM9S96 -> GM9S96 - FLASHING EE0
https://ghac.makekb.com/entry/786/