Goodman Gas Furnace: GM9S96
Re: Fault Codes
This furnace uses a 3-segment display to show status and fault codes.
All equipment errors will show a fault display starting with "E".
| EE0 | 3 Failures to Establish Flame |
|
| EE1 | Pressure Switch Contacts Stuck Closed |
|
| EE2 | Pressure Switch Contacts Filed to Close |
|
| EE3 | Primary Limit Circuit Open |
|
| EE4 | Flame Sensed with No Call for Heat |
|
| EE5 | Open Low Voltage Fuse |
|
| EE6 | Low Flame Signal |
|
| EEL | Problem with Igniter Circuit |
|
| EEA | Reversed Polarity |
|
| EEb | Gas Valve Error |
|
| EEC | Gas Valve Energized when it Should Not Be |
|
| E10 | Grounding Fault |
|
| E11 | Open Rollout Switch |
|
| EEn | Igniter Open |
|
| EEJ | Inducer Relay Error |
|
| EEH | Twinning Error |
|
| EEE | Control Internal Fault |
|