TUD/TDD - Flashing Code 4

Trane Gas Furnace: TUD/TDD

Re: Flashing Code 4

Code 4 = Limit switch open

There are 4 limits wired in series: a Reversed Flow Limit in the blower compartment (auto-reset), two Roll-Out Limits (manual-reset), and a Primary Limit (auto-reset).

Qty Possible Causes:
Bad Blower Motor/Capacitor
Bad Reversed Flow Limit 
Bad Heat Exchanger
Bad Roll-Out Limit
Furnace Over-Heating
Bad Primary Limit


CHECKOUT:

1. Check the Limit Circuit


2. Check Limits


3. Check Blower Motor


4. Check Burners/Heat Exchanger


5. Check Temperature Rise



Article ID: 767
Last updated: 17 Nov, 2025
Revision: 7
Equipment -> Gas Furnaces -> Trane -> TUD/TDD -> TUD/TDD - Flashing Code 4
https://ghac.makekb.com/entry/767/