YZE/YZH - High Discharge Temperature (Heating)

York Heat Pump: YZE/YZH

Re: High Discharge Temperature Fault (Heating)

A High Temperature Lockout is indicated by the following LED pattern on the outdoor unit control board:


X/L Output


Qty Possible Causes:
1 Low Refrigerant
Bad O/D Expansion Valve
2 Refrigerant Over-Charge
Bad Discharge Sensor
1 Stuck Contactor

CHECKOUT:

1. Check Refrigerant Pressures

Normal Pressure Range
Refrigerant 0-30 Deg O/D 30-50 Deg O/D
R410A
  • 75-100 Suction
  • 250-320 Discharge
  • 100-150 Suction
  • 250-375 Discharge

2. Check Sub-Cooling


3. Check Discharge Temperature


4. Check Discharge Sensor



Article ID: 763
Last updated: 4 Feb, 2025
Revision: 1
Equipment -> Heat Pumps -> York -> YZE/YZH -> YZE/YZH - High Discharge Temperature (Heating)