GMS9 - Flashing Code 3

Goodman Gas Furnace: GMS9

Re: Flashing Code 3

If, after the vent blower is energized, the pressure switch does not close, the control will keep the blower on and wait for the switch to close.

The diagnostic code for this problem is 3 short flashes followed by a pause.

► There are 2 pressure switches in the furnace:  One connected to the Inducer, and one connected to the collector box.

► Only the Inducer Pressure Switch will cause a Code 3.  (The condensate switch breaks power to the gas valve and will cause a Code 1).

► The diagnostic code will go away once the pressure switch closes.


Qty Possible Causes:
Bad Inducer Motor
1 Bad Pressure Switch
Water in the vent (improper slope)
Water in inducer (clogged drain)
Clogged / Frozen Drain
Item Stuck in Inducer Motor
Bad Ignition Control


CHECKOUT:

1. Check Control Board


2. Check Inducer Motor


3. Check "Inducer" Pressure Switch


4. Check Condensate Drainage



Article ID: 761
Last updated: 15 Jan, 2025
Revision: 7
Equipment -> Gas Furnaces -> Goodman -> GMS9\GCS9 -> GMS9 - Flashing Code 3
https://ghac.makekb.com/entry/761/