Trane Gas Furnaces: TUH2/TDH2
Re: Furnace Lockout Codes / Diagnostic Codes
INTEGRATED FURNACE CONTROL - ERROR CODES | |
Flashing Slow | Normal - No call for heat |
Flashing Fast | Normal - Call for heat |
On | Replace Control |
Off | Check Power |
2 Flashes | Lockout due to re-tries or recycles |
3 Flashes | Pressure switch fault (open or closed) |
4 Flashes | Open limit circuit |
5 Flashes | Flame sensed with no call for heat |
6 Flashes | Reversed polarity, low voltage or poor ground |
7 Flashes | Gas valve circuit error |
8 Flashes | Low flame signal |
9 Flashes | Check Ignitor, Possible grounding problem |
FAULT CODE RECOVERY
On power up, the last 4 faults, if any, will be flashed on the Red LED.
Fault Code Reset
The last 4 fault codes can be erased from memory by powering up the control with “G” energized and then applying “R” to the “W1” terminal 3 times within 6 seconds.