Bosch Heat Pump: M15, M18, M20
Re: Parameter Point Check Table
To display system parameters, press the “Check” button to index through the series of parameters available. The first time you press the “Check” button, it will display the sequence, and after 1 second it will display the value of the parameter. If you press the “Check” button again, it will display the next sequence.
If a system protection is active, first digit will display “status code”.
Parameter Point Check Table | |||
Param No. | Point Check Content | ||
0 | Outdoor Unit Capacity | ||
1 | Outdoor Unit Mode | ||
2 | Outdoor Unit Compressor Speed | ||
3 | Outdoor Coil Temperature (T3) | ||
4 | Outdoor Ambient Temperature (T4) | ||
5 | Compressor Discharge Temperature (T5) | ||
6 | Reserved | ||
7 | Liquid Line Temperature (T3L) | ||
8 | Computer Module Temperature (Tf) | ||
9 | Suction Pressure (PSI) | ||
10 | Head Pressure (PSI) | ||
11 | Target Evaporator Temperature (Cooling Mode) | ||
12 | Evaporator Temperature | ||
13 | Target Condensing Temperature (Heating Mode) | ||
14 | Condensing Temperature | ||
15 | Target Compressor Discharge Superheat (Heating Mode) | ||
16 | Compressor Discharge Superheat | ||
17 | EEV Position | ||
18 | Outdoor Fan Speed | ||
19 | Compressor Current | ||
20 | Inlet AC Voltage | ||
21 | Compressor DC Voltage | ||
22 | Compressor Runtime | ||
23 | Last Fault Code | ||
24 | Software Version | ||
25 | Remark |