Honeywell Thermostat: RTH6580 Wi-Fi FocusPro
Re: Installer Setup Options
To enter Installer Setup, press and hold the "Fan" button and the "Up" button together for at least 3 seconds until the display changes.
Setup# |
Function |
Options |
1 |
System Type |
- 0 = Gas, oil or electric heat with air conditioning
- 1 = 1 heat/1 cool heat pump
- 2 = Heat only (2-wire systems/power to open & close zone valves/normally open zone valves)
- 3 = Heat only with fan
- 4 = Cool only
- 5 = 2 heat/1 cool heat pump
- 6 = 2 heat/2 cool conventional
- 7 = 2 heat/1 cool conventional
- 8 = 1 heat/2 cool conventional
|
2 |
Rev Valve |
- 0 = Changeover valve (O/B terminal energized in cooling)
- 1 = Changeover valve (O/B terminal energized in heating)
|
3 |
Fan Control
|
- 0 = Gas or oil furnace — equipment controls fan in heating
- 1 = Electric furnace — thermostat controls fan in heating
|
4 |
|
|
5 |
Heat Cycle Rate
|
- 5 = For gas or oil furnaces of less than 90%efficiency
- 1 = For steam or gravity systems
- 3 = For hot water systems & furnaces of over 90% efficiency
- 9 = For electric furnaces
- [Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]
|
6 |
2nd Stg Ht Cycle Rate |
- 5 = For gas or oil furnaces of less than 90%efficiency
- 1 = For steam or gravity systems
- 3 = For hot water systems & furnaces of over 90% efficiency
- 9 = For electric furnaces
- [Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]
|
12 |
Changeover Type |
- 0 = Manual changeover (Heat/Cool/Off)
- 1 = Auto changeover (Heat/Cool/Auto/Off)
|
13 |
Smart Response |
|
14 |
Temperature Display |
- 0 = Fahrenheit
- 1 = Celsius
|
16 |
Schedule Options |
- 1 = Programmable (7-Day)
- 0 = Non-Programmable (Schedule Off)
|
36 |
Thermostat Name
|
|
39 |
Wireless Setup
|
- 0 = Disconnect thermostat from wireless system
- 1 = Thermostat is connected
|
42 |
Show Period and Day |
|
85 |
Restore Default Schedule |
- 0 = Use Custom Scheduling
- 1 = Restore to Default Energy Savings Schedule
|
90 |
Reset
|
- 0 = No reset
- 1 = Reset thermostat back to factory configuration
|