P3UR - Flashing Code 2

York Gas Furnace: P3UR / P3DH

Re: Flashing Code 2

Code 2 = Pressure switch stuck closed

The furnace pressure switch should only close when the inducer fan output is energized. If control board is not energizing the inducer fan output and the pressure switch circuit is closed, the board will flash a Code 2.

► A Code 2 will usually keep the inducer motor from starting (unless the relay is stuck) and the gas furnace from operating.


Qty Possible Causes:
1 Bad Pressure Switch
Inducer Fan Stuck On (Bad Control Board)
ADPS Switch Set Too Low


CHECKOUT:

1. Check Controller


2. Check Pressure Switch Contacts


3. ADPS Switch Setting



Article ID: 699
Last updated: 10 Jan, 2022
Revision: 5
Equipment -> Gas Furnaces -> York -> P3UR / P3DH -> P3UR - Flashing Code 2