Honeywell Thermostats: Prestige IAQ
Re: Configure 2-Stage Heat, 1-Stage Cool Heat Pump
Step 1: Enter Configuration Screen
First-Time Power-Up → Step 2. Enter Setup Information
Service Configuration ⇒ Go into "Installer Setup"
Step 2: Enter Setup Information below:
| Setup# | Description | Option |
| 1000 | LANGUAGE | English |
| 1010 | APPLICATION | "residential" or "commercial" |
| 1030 | THERMOSTAT NAME | Select Appropriate Name |
| 110 | SYSTEM ZONING | Not Zoned |
| ** CONNECT ** | ||
| EQUIPMENT INTERFACE NAME | EIM | |
| CONNECT OTHER REDLINK | No | |
| 1040 | SCHEDULING OPTION | Programmable |
| 1050 | TEMPERATURE SCALE | "fahenheit" |
| 1060 | OUTDOOR AIR SENSOR | No (Optional) |
| 2000 | HEATING SYSTEM | "heat pump" |
| 2010 | HEATING EQUIPMENT | "air to air heat pump" |
| 2060 | REVERSING VALVE | "o (o/b on cool)" |
| 2070 | STAGES | 1, 1 |
| 2180 | BACKUP HEAT TYPE | "electric" |
| 3000 | SYSTEM CHANGEOVER | "automatic", 3deg |
| 3010 | CONTROL OPTIONS | "advanced options" |
| 3021 | FINISH WITH HIGH HEAT | No |
| 3090 | BACKUP HEAT DROOP | 2.0 deg |
| 3110 | UPSTAGE TIMER BACKUP HT | Off |
| 3120 | OUTDOOR TEMP LOCKOUTS | Off, Off |
| 3140 | COMPRESSOR CYCLES STG 1 | 3 |
| 3160 | BACKUP HEAT CYCLES PER HR | 9 |
| 3240 | COMPRESSOR OFF TIME | 3 minutes |
| 3260 | EXTENDED FAN RUN TIMES | 60, 60 |
| 4000 | SCHEDULE PERIODS | "4 periods per day" |
| 4010 | PRE-OCCUPANCY PURGE | Off |
| 4020 | TYPE OF OVERRIDE | standard |
| 4030 | OVERRIDE DURRATION | 4 hours |
| 4050 | MIN HEAT RECOVERY RATE | 3º/hr |
| 4070 | MIN COOL RECOVERY RATE | 5º/hr |
| 4090 | ADAPTIVE RECOVERY | Yes |
| 4100 | TEMPERATURE RANGE STOPS | 64 deg, 82 deg |
| 4110 | KEYPAD LOCKOUT | "Unlocked" |
| 5000 | WHAT SENSORS CONNECTED | None |
| 6000 | WHAT DRY CONACTS | None |
| 7000 | FILTER TYPE | "media" |
| 7020 | NUMBER OF AIR FILTERS | 1 |
| 7110 | AIR FILTER | "reminder-off" |
| 8000 | HUMIDIFIER TYPE | "none" or "bypass-fan/pwrd" |
| 8030 | HUMIDIFIER WIRING | "t-stat terminal U1" |
| 8050 | WINDOW PROTECTION | Off |
| 8060 | USE HIMIDIFIER IN HEAT MODE | Yes |
| 8070 | HUMIDIFIER CONTROL | "hum when heat is on" |
| 8100 | HUMIDIFIER PAD | "reminder-off" |
| 9000 | DEHUM EQUIPMENT | "A/C with high fan" |
| 9070 | DEHUM OVER COOLING LIMIT | 1 deg |
| 9180 | DEHUM AWAY MODE | "not allowed" |
| 9210 | DEHUMIDIFIER FILTER | "reminder-off" |
| 10000 | VENTILATION TYPE | "none" |
| 10170 | VENTILATION FILTER | "reminder-off" |
| 11000 | NUMBER OF UV DEVICES | 0 |
| 12000 | CUSTOM REMINDERS | |
| 14000 | CLOCK FORMAT | "12 hour" |
| 14010 | DAYLIGHT SAVING TIME | On |
| 14020 | INDOOR OFFSETs | 0 deg, 0% |
| 15000 | DEALER INFORMATION | Name : "GHAC" |
| 15000 | DEALER INFORMATION | Phone: 606-836-8143 |
| 15010 | MORE DEALER INFORMATION | email: |
| 15010 | MORE DEALER INFORMATION | website: www.ghacinc.com |
| 15020 | DEALER MESSAGE |
Step 3: Press "Done"