YZF - Defrost Problem / Outdoor Coil Frozen

York Heat Pump: YZF

Re: Not Defrosting / Outdoor Coil Frozen

These units use a Yorkguard VI Demand Defrost control board.

The board uses an Ambient (outdoor) Sensor and Liquid Line Sensor to determine the proper conditions for defrost to occur.


Qty Possible Causes:
Bad Liquid Line Sensor
  Bad Condenser Fan Motor
Bad Fan Capacitor
  Bad Defrost Board
Mis-Located Sensor
Low Refrigerant Charge
Bad Expansion Valve


CHECKOUT:

1. Check Outdoor Fan


2. Check Defrost


3. Check Liquid Line Sensor


4. Check Ambient Sensor


5. Check Refrigerant Pressures

DEFROST MODE

Defrost Termination
Refrigerant Suction Pressure Discharge Pressure Liquid Line Temperature
R410A

100-120 Suction

300-375 Discharge

80-90 Deg

HEATING MODE

Normal Pressure Range
Refrigerant 0-30 Deg O/D 30-50 Deg O/D
R410A
  • 75-100 Suction
  • 250-320 Discharge
  • 100-150 Suction
  • 250-375 Discharge


Article ID: 667
Last updated: 23 Feb, 2021
Revision: 10
Equipment -> Heat Pumps -> York -> YZB / YZF -> YZF - Defrost Problem / Outdoor Coil Frozen