Carrier Heat Pump: 25HNB6
Re: Status Codes / Fault Codes
LOCKOUT CODES:
Amber LED | Description |
Constant On | No Demand / Standby |
1 - Pause | 1st Stage Compressor |
2 - Pause | 2nd Stage Compressor |
16 | System Communication Failure |
25 | Invalid Model Plug |
31 | Hi Pressure Switch Trip |
32 | Low Pressure or Discharge Temp Switch Trip |
45 | O/D Unit Control Board Failure |
46 | Low Line Voltage (Brown Out) |
47 | No Power Present at O/D Unit |
53 | Outdoor Temp Sensor Failure |
55 | Outdoor Coil Sensor Failure |
56 | Thermistors (Outdoor & Coil) Out of Range |
71 | Low Stage Thermal Cutout |
72 | High Stage Thermal Cutout |
73 | Contactor Stuck Closed |
74 | No Power at Compressor |
81 | Low Stage Thermal Cutout x 3 |
82 | High Stage Thermal Cutout x 3 |
83 | Low Pressure Switch Trip x 3 |
84 | High Pressure Switch Trip x 3 |