GPH14 - Defrost Problem / Outdoor Coil Frozen

Goodman Heat Pump: GPH14

Re: Defrost Problem, Outdoor Coil Frozen

The Goodman GPH14 Heat Pump uses a Time & Temperature Defrost Board.

Qty Possible Causes:
2 Bad or Disconnected Defrost Stat
2 Bad Defrost Board
Low Refrigerant Charge
Bad Cond Fan Motor / Capacitor
Mis-Located Defrost Stat
Stuck Reversing Valve
Defrost Timer Set Too Long

CHECKOUT:

1. Check Operating Status


2. Check Fan Motor


3. Check Defrost Board and Stat


4. Check Refrigerant Charge

Normal Pressure Range
Refrigerant 0-30 Deg O/D 30-50 Deg O/D
R410A
  • 70-100 Suction
  • 250-320 Discharge
  • 100-135 Suction
  • 250-375 Discharge


Article ID: 658
Last updated: 21 Dec, 2020
Revision: 8
Equipment -> Package Units -> Goodman -> GPH14 -> GPH14 - Defrost Problem / Outdoor Coil Frozen
https://ghac.makekb.com/entry/658/