13HPX - Defrost Problem / Outdoor Coil Frozen

Lennox Heat Pump: 13HPX

Re: Defrost Problem/Outdoor Coil Frozen

The Lennox 13HPX Heat Pump uses a Time & Temperature Defrost Board in combination with a Defrost Thermostat (S6).

Defrost Initiation


Qty Possible Causes:
2 Bad S6 Defrost Stat
Bad Defrost Board
Low Refrigerant Charge
Bad Cond Fan Motor / Capacitor
Stuck Reversing Valve
Bad Reversing Valve Solenoid Coil

CHECKOUT:

1. Check Operating Status


2. Check Fan Motor


3. Check Refrigerant Charge

Normal Pressure Range
Refrigerant 0-30 Deg O/D 30-50 Deg O/D
R-410A
  • 75-100 Suction
  • 250-320 Discharge
  • 100-150 Suction
  • 250-375 Discharge

4. Check Defrost Thermostat


5. Check Defrost Board


6. Check Reversing Valve / Solenoid Coil