YHJF - High Pressure Lockout - Heating Mode

York Heat Pump: YHJF

Re: High Pressure Lockout - Heating Mode

The heat pump was running in normal heat mode (not in defrost) and the high pressure switch tripped.


Qty Possible Causes:
1 Refrigerant OverCharge
 1 Bad O/D Expansion Valve
Bad Blower Motor / Capacitor
Low Indoor Airflow
Refrigerant Restriction
Bad Pressure Switch

CHECKOUT:

1. Check Indoor Airflow


2. Check Blower Motor


3. Check Refrigerant Pressures

Normal Pressure Range
Refrigerant 0-30 Deg O/D 30-50 Deg O/D
R410A
  • 75-100 Suction
  • 250-320 Discharge
  • 100-150 Suction
  • 250-375 Discharge

4. Check Sub-Cooling


5. Check Heat Pump Temperature Rise


6. Check Indoor Airflow


7. Check Duct Static Pressure