GMS9 - Flashing Code 1 - Won't Ignite

Goodman Gas Furnace: GMS9/GMD9/GMH9

Re: Code 1 / Won't Ignite

Code 1 = 3 Failed Ignition Attempts

► Be aware that the furnace Condensate Pressure Switch breaks power to the gas valve and will cause a Fault Code 1 (Does not cause a Code 3).


Qty Possible Causes:
Dirty Flame Sensor
Bad Ignitor
Bad Control Board
1 Clogged Drain 
Tripped Auxiliary Limit
Bad Gas Valve


CHECKOUT:

1. Check Ignition Sequence


2. Check Glow Plug


3. Check Ignition


4. Check Control Board Output


5. Check Gas Pressure / Valve


6. Check Flame Sensor


7. Check Furnace Drains



Article ID: 619
Last updated: 20 Jan, 2020
Revision: 14
Equipment -> Gas Furnaces -> Goodman -> GMS9\GCS9 -> GMS9 - Flashing Code 1 - Won't Ignite