YM9M - Flashing Code 3

York 90% Gas Furnace: YM9M

Re: Flashing Code 3

Code 3 = Furnace Pressure Switch failed to close on a call for heat.

►The code description on the blower door may say, "Vent or Termination Problem" which is a possible cause, but not the most likely.


This gas furnace has two pressure switches:

► ONLY the PS1 switch will generate a Code 3. (PS2 is wired in series with the Roll-Out Switches and will generate a Code 5).


Qty Possible Causes:
Bad Inducer Motor
2 Bad Vent Pressure Switch
1 Water in Pressure Hose
Bad Pressure Transducer
Water in the vent (improper slope)
Item Stuck in Inducer Motor
Bad Control Board


CHECKOUT:

1. Check Control Board


2. Check Inducer


3. Check Pressure Switches


4. Check Condensate Drainage




Article ID: 603
Last updated: 13 Mar, 2019
Revision: 11
Equipment -> Gas Furnaces -> York -> YM9M -> YM9M - Flashing Code 3
https://ghac.makekb.com/entry/603/