XP13 - High Pressure - Heating

Lennox XP13 Heat Pump: Heating

Re: High Pressure Fault/Lockout

There are two different High Pressure Indications:

High Pressure Fault occurs when the Hi Pressure Switch opens and is indicated by a Slow Flashing Green LED on the outdoor unit control board.

High Pressure Lockout occurs after the 5th High Pressure Fault during a single compressor cycle and is indicated by a Solid On Green LED on the outdoor unit control board.

► There is a schrader valve under the high pressure switch for replacement.


Qty Possible Causes:
Refrigerant OverCharge
Bad Expansion Valve
Bad Blower Motor / Capacitor
1 Stuck Defrost Stat
Low Indoor Airflow
Refrigerant Restriction
Bad Pressure Switch


CHECKOUT:

1. Check Indoor Airflow


2. Check Blower Motor


3. Check Refrigerant Pressures


4. Check Sub-Cooling


5. Check Defrost Cycle


6. Check Air Filter & Indoor Coil


7. Check Duct Static Pressure